Description

The ebmpapst K3G310-PT08-J2 is a high-performance EC centrifugal fan module engineered for precision HVAC and Fan Filter Unit (FFU) applications. This unit utilizes GreenTech EC motor technology, combining the efficiency of direct current with the robustness of alternating current mains supply. The backward-curved impeller design ensures high static pressure capabilities, essential for overcoming resistance in HEPA/ULPA filtration systems and complex ductwork. The integrated electronics provide intelligent control, allowing for precise speed modulation and energy optimization in demanding industrial environments.

Technical Specifications:
Manufacturer: ebmpapst
Model Number: K3G310-PT08-J2
Series: K3G RadiPac
Product Type: EC Centrifugal Fan Module
Impeller Type: Backward-curved, 7 blades
Impeller Diameter: 310 mm
Nominal Voltage: 400 V AC (3-Phase)
Frequency: 50/60 Hz
Power Consumption: 1230 W
Nominal Speed: 3010 RPM
Current Draw: 1.9 A
Impeller Material: Sheet aluminum
Electronics Housing: Die-cast aluminum
Motor Bearing: Maintenance-free Ball Bearings
Degree of Protection: IP55
Insulation Class: F
Ambient Temperature Range: -40°C to +80°C
Control Interface: 0-10 VDC / PWM / Modbus
Mounting Configuration: Free Standing / Support Bracket
Gross Weight: 15.0 kg

Industrial Application:
This specific model is optimized for critical air handling scenarios requiring variable air volume (VAV) and constant pressure control. It is predominantly deployed in semiconductor cleanroom FFUs, data center precision cooling units, and pharmaceutical air handling systems where continuous operation and thermal management are critical. The integrated electronics allow for seamless integration into Building Management Systems (BMS), ensuring Technical Compatibility with existing automation logic. The IP55 rating ensures durability against dust and moisture ingress in industrial environments.

Procurement Note:
We supply Original Engineering components to ensure system longevity and performance adherence. Contact us for current Lead Time and specific integration support regarding the K3G310 series.

Key Attributes
Mounting: Free Standing
Voltage: 400V
Blade Material: Sheet aluminum
Customized support: OEM, ODM
Warranty: 1 Year
After-sales Service Provided: Online support
Place of origin: Germany
Brand name: Ebmpapst
Product name: K3G310-PT08-J2
Current: 1.9A
Voltage: 400V
Specifications: 310mm
Port: Tianjin port
Power: 1230W
Degree of protection: IP55
Ambient temperature: -40°C-80℃
Insusation class: F
Motor bearing: Ball bearing

Packaging and Delivery
Selling Units: Single item
Single package size: 47X47X42 cm
Single gross weight: 15.000 kg

ebmpapst K3G310-PT08-J2 K3G310-PT08-J4 400V AC 1230W 3010RPM FFU HVAC Fan Filter Unit Centrifugal Fan K3G310-PT08-J1

ebmpapst K3G310-PT08-J2 K3G310-PT08-J4 400V AC 1230W 3010RPM FFU HVAC Fan Filter Unit Centrifugal Fan K3G310-PT08-J1

ebmpapst K3G310-PT08-J2 K3G310-PT08-J4 400V AC 1230W 3010RPM FFU HVAC Fan Filter Unit Centrifugal Fan K3G310-PT08-J1

ebmpapst K3G310-PT08-J2 K3G310-PT08-J4 400V AC 1230W 3010RPM FFU HVAC Fan Filter Unit Centrifugal Fan K3G310-PT08-J1

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Fans Maintenance and upkeep

1. The use environment should always be kept clean and tidy, the surface of the fan should be kept clean, there should be no sundries in the inlet and outlet air outlets, and the dust and other sundries in the fan and pipes should be cleaned regularly;

2. The fan can only operate under the condition that it is completely normal, and at the same time, it is necessary to ensure that the capacity of the power supply facilities is sufficient and the voltage is stable.

3. During the operation of the fan, if it is found that the fan has abnormal sound, the motor is seriously heated, the shell is live, the switch trips, and cannot be started, it should be stopped immediately for inspection. In order to ensure safety, maintenance is not allowed during the operation of the fan, and a test run should be carried out for about five minutes after the overhaul to confirm that there is no abnormal phenomenon before starting the operation;

4. The fan should be stored in a dry environment to avoid moisture on the motor. When the fan is stored in the open air, there should be defensive measures. In the process of storage and handling, the fan should be prevented from bumping to avoid damage to the fan.

FAQ

Spartro is a trusted supplier of industrial and home appliance spare parts, offering high-quality components for cooling systems, HVAC units, vacuum cleaners, printers, compressors, CNC machines, and more. We provide reliable products, competitive prices, and fast worldwide delivery.

First published time: 2025-10-22 04:12:51

Last updated time: 2026-01-31 12:25:33