Description
The Huawei UPS5000-A-500K is an elite-tier Online Double Conversion UPS with dimensions of 2000 x 1200 x 850 mm. This high-density power system delivers a formidable 500kVA (500kW) capacity, maintaining a perfect 1.0 output power factor for maximum load-carrying capability. Engineered for large-scale 3-phase infrastructures (380V/400V/415V), it represents the cutting edge of power electronics, converting unstable grid input into a pristine, continuous sine wave output with zero transfer time.
Designed as an integrated 2-meter tall industrial cabinet, the UPS5000-A-500K is optimized for the most demanding environments, including hyperscale data centers, large-scale financial clearing hubs, and critical healthcare imaging centers. Despite its massive power output, it maintains the same compact footprint as the 400kVA model, providing a significant boost in power density. With a peak system efficiency of 96% and full digital control, this 500kVA unit minimizes energy waste while providing the highest level of power availability for modern digital enterprises.
UPS5000-A-500K Parameters
- Manufacturer: Huawei
- Model Number: UPS5000-A-500K
- UPS Type: Online Double Conversion (AC-DC-AC)
- Rated Capacity: 500kVA / 500kW
- Output Power Factor: 1.0
- System Efficiency: Up to 96% (Typical load efficiency ≥ 95%)
- Operating Temperature: 0 – 40 ºC
- Storage Temperature: -40 to 70 ºC
- Relative Humidity: 0% – 95% (No condensing)
- Operating Altitude: 0 – 1000 m (Derating required according to EN/IEC 62040-3 above 1000 m)
- Audible Noise: ≤ 75 dB (Acoustically optimized for high-power cooling)
- Cooling Mode: Intelligent forced air cooling with independent fan-tray monitoring
Input Characteristics
- Input Wiring: 3Ph + N + PE
- Rated Voltage: 380Vac / 400Vac / 415Vac
- Input Voltage Range: 138 – 485 Vac (Wide window to minimize battery usage)
- Input Frequency Range: 40 – 70 Hz
- Input Power Factor: 0.99 (Full load)
- THDi: < 3% (Linear full load)
Output Characteristics
- Output Wiring: 3Ph + N + PE
- Output Voltage: 380Vac / 400Vac / 415Vac ± 1% (Steady state)
- Output Frequency: 50/60 Hz Auto-adaptive
- Frequency Stability: ± 0.05% (Internal clock synchronization)
- Overload Capacity: 110% for 60 min; 125% for 10 min; 150% for 1 min
- Waveform: Pure Sine Wave
Battery & Management
- Battery Voltage: 360 – 528 Vdc (Flexible string: 30 – 44 batteries; Default: 40)
- Charging Power: High-capacity charger with intelligent temperature compensation
- Control Interface: 7-inch to 10-inch Color Touchscreen HMI
- Connectivity: RS485, FE (SNMP/Modbus), Dry Contacts, Optional Smart Slots
Physical Properties
- Overall Dimensions: 2000 x 1200 x 850 mm
- Form Factor: Floor-standing Heavy-duty Cabinet
- Net Weight: 850 kg
- Protection Level: IP20
Core Value & Features
- Industry-Leading Power Density: Delivers 500kW of power in a standard 1.2m wide cabinet, offering the best-in-class power-to-footprint ratio for large data centers.
- Superior PUE Support: High online efficiency (96%) significantly contributes to reducing the overall Power Usage Effectiveness (PUE) of the facility.
- Robust Fault Tolerance: Features a redundant fan and control power design, ensuring no single point of failure within the internal cooling or control systems.
- Intelligent O&M: Real-time health monitoring of key components (capacitors, fans, batteries) allows for predictive maintenance, moving from reactive to proactive service.